The equipment is eight-channel battery analyzer suitable for most applications in battery testing fields such as electrode materials research, battery performance & cycle test, small-scale battery formation, capacity grading, battery pack testing and etc.
Basic Info
Model NO.: CY-BTS-5V10mA
Test Region: Current
Customized: Customized
Record Frequency: 1Hz
Interface: R232
Transport Package: Wooden Box
Origin: Zhengzhou, China
Type: Batteries Monomer Tester
Application: Lithium-ion Battery
Noise: <85dB
Current Response Time: 20 Ms
Trademark: CY
Specification: 5V10mA
HS Code: 85141090
Product Description
BTS-5V10mA Battery Testing Equipment
Introduction
The equipment is eight-channel battery analyzer suitable for most applications in battery testing fields such as electrode materials research, battery performance & cycle test, small-scale battery formation, capacity grading, battery pack testing and etc.
Project index | Parameter index | |
Input Power | AC 220V ±10% / 50Hz | |
resolution | AD:15bit;DA:12bit | |
Input Resistance | ≥1MΩ | |
Input Power | 747mW | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | Charging:10mV~5V Discharging: 1.5V-05V |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Current | Per Channel Current Range | 0.02mA~10mA |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Power | Per Channel Output Power | 50mW |
Stability | ± 0.2% of FS | |
Time | Current Response Time | 20ms (0-Full Range) |
Step Time Range | 1s≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) | |
Data Recording | Record Condition | Time△t:1S-60000S |
Voltage△U: 10mV-5V | ||
Current△I: 0.02mA-10mA | ||
Record Frequency | 1Hz | |
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge |
End Condition | Voltage,Current,Relative Time,Capacity | |
Discharge | Discharge Mode | CCD,CPD |
End Condition | Voltage,Current,Relative Time,Capacity, | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 63 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Software Protection | Power-down Data Protection |
Off-line Testing Function | ||
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time | ||
Hardware Protection | Additional Anti-reverse Protection Model | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <85dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP/IP Protocol | |
Data Output | EXCEL2003/2010,TXT | |
Communication Interface | R232 | |
Per Unit Main Channels No. | 8 | |
Dimensions | 3U,482*378*130(mm) |
Equipment Working Environment
Project index | Parameter index |
Working Temperature Range | -10ºC~40ºC |
Storage Temperature Range | -10ºC~50ºC |
Working Environment Relative Humidity Range | =<70% RH |
Storage Environment Relative Humidity Range | =< 80% RH |